PIMS MEDICAL COLLEGE HOSPITAL HOSPITAL BUILDINGS PIMS MEDICAL COLLEGE HOSPITAL PESHAWAR, KPK, PAKISTAN CLIENT: Khan Architect & Dr. Tariq SaifiCOVERED AREA: 325,000 ft² PROJECT DESCRIPTION HVAC: 1075 Tons Water cooled electric operated screw chillers based central cooling system.Plumbing: Water supply and drainage work.Electrical: 2.8 MW electrical load & allied works.Fire Fighting: 1000 GPM Sprinkler, Fire Hydrant, FHC System and Fire Extinguishers.
PNS HAFEEZ HOSPITAL
PNS HAFEEZ HOSPITAL HOSPITAL BUILDINGS PNS HAFEEZ HOSPITAL ISLAMABAD, PAKISTAN CLIENT: Anwar Ali Architect & PNS Directorate Works IslamabadCOVERED AREA: 575,000 ft² PROJECT DESCRIPTION HVAC: 1920 tons water cooled electric operated centrifugal chillers based central cooling system.Plumbing: Water supply, drainage work, recycling of water & medical gases.Electrical: 4.6 MW electrical load & allied works.Fire Fighting: 1500 GPM Sprinkler, Fire Hydrant, FHC System and Fire Extinguishers.
FALETTI’S EXPRESS
FALETTI’S EXPRESS HOTEL & RECREATIONAL FALETTI’S EXPRESS MULTAN, PUNJAB, PAKISTAN COVERED AREA: 81,300 ft² PROJECT DESCRIPTION HVAC: 390 tons water cooled electric operated screw chillers based central cooling system.Plumbing: Water supply, drainage work & medical gases.Electrical: 1.1 MW electrical load & allied works.Fire Fighting: 750 GPM Sprinkler, Fire Hydrant & FHC System and Fire Extinguishers.
KORANG RIVER RESORT
KORANG RIVER RESORT HOTEL & RECREATIONAL KORANG RIVER RESORT MURREE EXPRESSWAY. GALIYAT. PAKISTAN CLIENT: Mr. Khaliq ZamanCOVERED AREA: 153,200 ft² PROJECT DESCRIPTION HVAC: 511 tons air cooled reversible electric operated screw based central cooling system for complete building.Plumbing: Water supply and drainage work.Electrical: 1.6 MW electrical load & allied works.Fire Fighting: 1250 GPM Dry Type Sprinkler, Fire Hydrant & FHC System and Fire Extinguishers.
WAJEHAT AL NAJRAN
WAJEHAT AL NAJRAN HOTEL & RECREATIONAL WAJEHAT AL NAJRAN NAJRAN, SAUDI ARABIA CLIENT: Ali HarithiCOVERED AREA: 823,74 ft² PROJECT DESCRIPTION HVAC: 4700 tons air cooled reversible electric operated screw based central cooling system & Packaged Units.Plumbing: Water supply. drainage work.Electrical: 8.37 MW electrical load & allied works.Fire Fighting: 1500 GPM Sprinkler, Fire Hydrant & FHC System and Fire Extinguishers.
HAMPTON INN BY HILTON
HAMPTON INN BY HILTON HOTEL & RECREATIONAL HAMPTON INN BY HILTON KINGDOM OF SAUDI ARABIA CLIENT: Nofel Ali Yazdani ArchitectCOVERED AREA: 974,000 ft² PROJECT DESCRIPTION HVAC: 3260 tons air cooled electric operated screw chillers based central cooling system.Plumbing: Water supply, drainage work, steam piping.Electrical: 9.1 MW electrical load & allied works.Fire Fighting: 1500 GPM Sprinkler. Fire Hydrant, FHC System and Fire Extinguishers.
TABUK PLAZA
TABUK PLAZA RETAIL & COMMERCIAL BUILDINGS TABUK PLAZA TABUK, SAUDI ARABIA CLIENT: Sarah Technical CoCOVERED AREA: 276,973 ft² PROJECT DESCRIPTION HVAC: 980 tons air cooled reversible electric operated screw based central cooling system for complete building.Plumbing: Water supply, drainage work & medical gases.Electrical: 2.81 MW electrical load & allied works.Fire Fighting: 1250 GPM Sprinkler, Fire Hydrant & FHC System and Fire Extinguishers.
FOOD COURT, STAR AVENUE
FOOD COURT, STAR AVENUE RETAIL & COMMERCIAL BUILDINGS FOOD COURT, STAR AVENUE JEDDAH, SAUDI ARABIA CLIENT: Al Aiban GroupCOVERED AREA: 54,574 ft² PROJECT DESCRIPTION HVAC: 408 tons Packaged Type system for complete building.Plumbing: Water supply and drainage work.Electrical: Electrical load & allied works.Fire Fighting: Sprinkler, Fire Hydrant & FHC System and Fire Extinguishers.
JAWARHAT AL ABHA
JAWARHAT AL ABHA RETAIL & COMMERCIAL BUILDINGS JAWARHAT AL ABHA ABHA, SAUDI ARABIA CLIENT: Arabian CentersCOVERED AREA: 472,170 ft² PROJECT DESCRIPTION HVAC: 1950 tons air cooled reversible electric operated screw based central cooling system & Package Units.Plumbing: Water supply and drainage work.Electrical: 4.2 MW electrical load & allied works.Fire Fighting: 1500 GPM Sprinkler, Fire Hydrant & FHC System and Fire Extinguishers.
MADINAH BOULEVARD
MADINAH BOULEVARD RETAIL & COMMERCIAL BUILDINGS MADINAH BOULEVARD MADINAH, SAUDI ARABIA CLIENT: Arabian CentersCOVERED AREA: 638,337 ft² PROJECT DESCRIPTION HVAC: 2980 tons air cooled reversible electric operated screw based central cooling system for complete building.Plumbing: Water supply. drainage work & recycling of water.Electrical: 6.3 MW electrical load & allied works.Fire Fighting: 1830 GPM Sprinkler, Fire Hydrant & FHC System and Fire Extinguishers.